48T human anti-catenin antibody ELISA test kit

Human anti-catenin antibody ELISA test kit

Test principle:
The Titin-Ab kit is a solid-phase sandwich enzyme-linked immunosorbent assay (ELISA). Standards with known concentrations of Titin-Ab and samples with unknown concentrations are added to microwell enzyme plates for detection. First, Titin-Ab and biotin-labeled antibody were incubated at the same time. After washing, HRP labeled with avidin was added. After incubation and washing, the unbound enzyme conjugate is removed, and then substrates A and B are added to act simultaneously with the enzyme conjugate. Produce colors. The color depth is proportional to the concentration of Titin-Ab in the sample.

Bring your own material distilled water.
Sampler: 5ul, 10ul, 50ul, 100ul, 200, 500ul, 1000ul.
Oscillator and magnetic stirrer etc.

Safety Avoid direct contact with the stop solution and substrates A and B. Once exposed to these liquids, rinse with water as soon as possible.
Do not eat, drink, smoke or use cosmetics during the experiment.
Do not use your mouth to absorb any ingredients in the kit.

Human anti-catenin antibody ELISA test kit

Handling precautions Reagents should be stored according to label instructions, and returned to room temperature before use. The sparse standards should be discarded and cannot be stored.
The slats not used in the experiment should be immediately returned to the packaging bag, sealed and stored to avoid deterioration.
Unused other reagents should be packed or covered. Do not mix reagents of different batches. Use before warranty.
Use a disposable pipette tip to avoid cross-contamination, and avoid using a sampler with a metal part when drawing the stop solution and substrates A and B.
Use a clean plastic container to prepare the washing solution. Mix all components and samples in the kit thoroughly before use.
When washing the enzyme-labeled plate, it should be fully patted dry. Do not put the absorbent paper directly into the enzyme-labeled reaction well to absorb water.
Substrate A should evaporate to avoid opening the lid for a long time. Substrate B is sensitive to light and avoid prolonged exposure to light. Avoid contact with hands, it is toxic. The OD value should be read immediately after the experiment is completed.
The order of adding reagents should be the same to ensure that all wells are incubated for the same time.
Perform the incubation operation according to the time, the amount and order of the liquid indicated in the instructions.

Human anti-catenin antibody ELISA test kit

Sample collection, processing and storage methods Serum-avoid any cell stimulation during the operation. Use test tubes free of pyrogens and endotoxins. After collecting blood, centrifuge at 1000 × g for 10 minutes to separate the serum and red blood cells quickly and carefully.
Plasma ----- EDTA, citrate, heparin plasma can be used for detection. Centrifuge at 1000 × g for 30 minutes to remove particles.
The cell supernatant was centrifuged at 1000 × g for 10 minutes to remove particles and polymers.
Tissue homogenate ----- Mash the tissue with appropriate amount of saline. Centrifuge at 1000 × g for 10 minutes, and take the supernatant for storage. If the sample is not used immediately, it should be divided into small parts and stored at -70 ℃ to avoid repeated freezing. If possible, do not use hemolysis or hyperlipidemia. If there are a large number of particles in the serum, centrifuge or filter before testing. Do not thaw at 37 ° C or higher. Thaw at room temperature and ensure that the sample is thawed evenly and adequately.

Human anti-catenin antibody ELISA test kit

Before use, mix all reagents thoroughly. Don't make the liquid generate a lot of foam, so as to avoid adding a large number of bubbles during sample addition, which will cause errors in sample addition.
The number of slats required is determined by the number of samples to be tested plus the number of standard products. It is recommended to make multiple holes for each standard and blank hole. Each sample is determined according to its own quantity, and those that can use multiple holes can be used as much as possible. The specimen was diluted 1: 1 with the specimen dilution solution and then added 50ul to the reaction well.
Add 50ul of the diluted standard to the reaction well and 50ul of the sample to be tested in the reaction well. Immediately add 50ul of biotin-labeled antibody. Cover the membrane plate, gently shake and mix, and incubate at 37 ° C for 1 hour.
Shake off the liquid in the wells, fill each well with washing liquid, shake for 30 seconds, shake off the washing liquid, pat dry with absorbent paper. Repeat this operation 3 times. If washing with a plate washer, the number of washes is increased once.
Add 80 ul of streptavidin-HRP to each well, gently shake and mix, and incubate at 37 ° C for 30 minutes.
Shake off the liquid in the wells, fill each well with washing liquid, shake for 30 seconds, shake off the washing liquid, pat dry with absorbent paper. Repeat this operation 3 times. If washing with a plate washer, the number of washes is increased once.
Add 50ul of substrate A and B to each well, mix gently by shaking, and incubate at 37 ° C for 10 minutes. Avoid light.
Remove the enzyme labeling plate and quickly add 50ul of stop solution. After adding the stop solution, the results should be measured immediately.
The OD value of each well was measured at a wavelength of 450 nm.

Limitation
The results of standard No. 6 and above are non-linear, and accurate results cannot be obtained based on this standard curve.

Kit performance
1. Sensitivity: The smallest detection concentration is less than No. 1 standard. Linearity of dilution. The correlation coefficient R between the linear regression of the sample and the expected concentration is 0.990.
2. Specificity: Does not react with other cytokines.
3. Repeatability: The coefficients of variation within and between plates are less than 10%.

Human anti-catenin antibody ELISA test kit

Judgment and analysis of results
1. Instrument value: read the OD value of each well on a microplate reader with a wavelength of 450nm
2. Taking the absorbance OD value as the ordinate (Y) and the corresponding Titin-Ab standard concentration as the abscissa (X), make the corresponding curve. The sample's Titin-Ab content can be converted from the standard curve according to its OD value The corresponding concentration.
3. Range of detection value: 0-240IU / L
4. Sensitivity: 0.1 IU / LNADPH anti-reducing Coenzyme II antibody 0.2ml
proCNP / NPPC (pro-natriuretic peptide) natriuretic peptide precursor C antibody 0.2ml
human IgM / PE fluorescein PE labeled human IgM 0.1ml
human IgA / PE fluorescein PE labeled human IgA 0.1ml
Monkey IgG / PE Fluorescein PE labeled monkey IgG 0.1ml
Monkey IgM / PE Fluorescein PE labeled monkey IgM 0.1ml
NP (Nonylphenol) 0.2ml
NPY (Neuropeptide Y) 0.1ml
NPY (Neuropeptide Y) 0.2ml

Flexible, Printed Laminated Films for Packaging

Printed laminate films for packaging are still the most popular and versatile type of flexible film we provide. Laminated films can be supplied in up to five layers in OPP, LDPE, PET, paper and foils with an infinite variety of combinations to create exactly the right look, feel and functionality.

 

Laminating films are increasingly being used by innovative companies looking for new ways of packing and presenting their products.  The strength and flexibility of laminate films makes them ideal for cooking, frozen foods, drink sachets, snack products and pet foods. The robust nature of laminate films, coupled with the ability to display print to a high definition standard means they remain one of our best-selling Packaging Film products

 

Paper laminates are creating some of the most innovative finished packs using strong materials with state-of the-art barrier properties whilst presenting a more traditional paper look and feel often preferred by the consumer. Combined with Somipack`s high definition print capability, laminates create some of the most eye-catching designs. They also provide practical advantages such as puncture resistance, barrier capabilities and qualities suitable for frozen foods. Laminate films can be supplied for ovenable, microwavable and retortable applications.

 

We offer clear, metalized, and foil structures, and film can be printed in up to 12 colors.

We take seriously the environmental aspect of laminating films and often work with users to create laminate films thinner and easier to recycle.

Packaging Film

Plastic Shrink Wrap,Shrink Wrap Film,Pvc Shrink Film,Plastic Film Packaging

Chaozhou Chao'an Xinmin Food Packaging Co., Ltd. , https://www.somipack.com

Posted on