Spot Human (Leptin) ELISA Test Kit

This reagent is for research use only: Serum or plasma test principle: ELISA detection kit Leptin kit is a solid-phase sandwich method enzyme-linked immunosorbent assay (ELISA). Standards with known concentration of Leptin and samples with unknown concentration are added to microwells The detection is carried out in the microplate. Incubate Leptin and biotin-labeled antibody first. After washing, HRP labeled with avidin was added. After incubation and washing, the unbound enzyme conjugate is removed, and then substrates A and B are added to act simultaneously with the enzyme conjugate. Produce colors. The color depth is proportional to the concentration of Leptin in the sample. Bring your own material distilled water. Sampler: 5ul, 10ul, 50ul, 100ul, 200ul, 500ul, 1000ul. Oscillator and magnetic stirrer etc. Safety Avoid direct contact with the stop solution and substrates A and B. Once exposed to these liquids, rinse with water as soon as possible. Do not eat, drink, smoke or use cosmetics during the experiment. Do not use your mouth to absorb any ingredients in the kit. Handling precautions Reagents should be stored according to label instructions, and returned to room temperature before use. The sparse standards should be discarded and cannot be stored. The slats not used in the experiment should be immediately returned to the packaging bag, sealed and stored to avoid deterioration. Other reagents used should be packed or covered. Do not mix reagents of different batches. Use before warranty. Use a disposable pipette tip to avoid cross-contamination, and avoid using a sampler with a metal part when drawing the stop solution and substrates A and B. Use a clean plastic container to prepare the washing solution. Mix all components and samples in the kit thoroughly before use. When washing the enzyme-labeled plate, it should be fully patted dry. Do not put the absorbent paper directly into the enzyme-labeled reaction well to absorb water. Substrate A should evaporate to avoid opening the lid for a long time. Substrate B is sensitive to light and avoid prolonged exposure to light. Avoid contact with hands, it is toxic. The OD value should be read immediately after the experiment is completed. The order of adding reagents should be the same to ensure that all wells are incubated for the same time. Perform the incubation operation according to the time, the amount and order of the liquid indicated in the instructions. Sample collection, processing and storage methods Serum-avoid any cell stimulation during the operation. Use test tubes free of pyrogens and endotoxins. After collecting blood, centrifuge at 1000 × g for 10 minutes to separate the serum and red blood cells quickly and carefully. Plasma ----- EDTA, citrate, heparin plasma can be used for detection. Centrifuge at 1000 × g for 30 minutes to remove particles. The cell supernatant was centrifuged at 1000 × g for 10 minutes to remove particles and polymers. Storage ------ If the sample is not used immediately, it should be divided into small parts and stored at -70 ℃ to avoid repeated freezing. If possible, do not use hemolysis or hyperlipidemia. If there are a large number of particles in the serum, centrifuge or filter before testing. Do not thaw at 37 ° C or higher. Thaw at room temperature and ensure that the sample is thawed evenly and adequately. Dilution of washing buffer (50 ×): 50-fold dilution with distilled water. Before use, mix all reagents thoroughly. Don't make the liquid generate a lot of foam, so as to avoid adding a large number of bubbles during sample addition, which will cause errors in sample addition. The number of slats required is determined by the number of samples to be tested plus the number of standard products. It is recommended to make multiple holes for each standard and blank hole. Each sample is determined according to its own quantity, and those that can use multiple holes can be used as much as possible. Add 50ul of the diluted standard to the reaction well and 50ul of the sample to be tested in the reaction well. Immediately add 50ul of biotin-labeled antibody. Cover the membrane plate, gently shake and mix, and incubate at 37 ° C for 1 hour. Shake off the liquid in the wells, fill each well with washing liquid, shake for 30 seconds, shake off the washing liquid, pat dry with absorbent paper. Repeat this operation 3 times. If washing with a plate washer, the number of washes is increased once. Add 80 ul of streptavidin-HRP to each well, gently shake and mix, and incubate at 37 ° C for 30 minutes. Shake off the liquid in the wells, fill each well with washing liquid, shake for 30 seconds, shake off the washing liquid, pat dry with absorbent paper. Repeat this operation 3 times. If washing with a plate washer, the number of washes is increased once. Add 50ul of substrate A and B to each well, mix gently by shaking, and incubate at 37 ° C for 10 minutes. Avoid light. Remove the enzyme labeling plate and quickly add 50ul of stop solution. After adding the stop solution, the results should be measured immediately. The OD value of each well was measured at a wavelength of 450 nm. The results above the No. 6 standard are non-linear, and accurate results cannot be obtained based on this standard curve. Kit performance 1. Sensitivity: The minimum detection concentration is less than No. 1 standard. Linearity of dilution. The correlation coefficient between the linear regression of the sample and the expected concentration is 0.990. 2. Specificity: Does not react with other cytokines. 3. Repeatability: The coefficients of variation within and between plates are less than 10%. Judgment and analysis of results 1. Instrument value: read the OD value of each well on a microplate reader with a wavelength of 450 nm. 2. Take the absorbance OD value as the ordinate (Y), and the corresponding Leptin standard concentration as the abscissa (X) The corresponding curve is made, and the Leptin content of the sample can be converted from the standard curve to the corresponding concentration according to its OD value. 3. Detection value range: 0-40nmol / L4, sensitivity: 0.1 nmol / L prostate specific antigen immunoassay X142261 -20 ℃, avoid light 150ng / branch 150543-0004 alpha-fetoprotein immunoassay X142262 -20 ℃, avoid Light 800ng / 661IU / branch 150542-0004 X142263 for carcinoembryonic antigen immunoassay -20 ℃, dark 320ng / branch 150541-0210 for ferritin immunoassay X142264 -20 ° C, dark 2ug / branch 540-9410 human placental prolactin (HPL) X142265 for immunoassay -20 ℃, protected from light 14.2μg / branch 150536-9903 Human chorionic gonadotropin β subunit Immunoassay X142266 -20 ℃, protected from light 240ng / 0.5ml / branch 150535-201002 growth hormone Immunoassay X142267 -20 ° C, dark 1.22mIU / 0.61ug / branch 534-9604 Follitropin immunoassay X142268-20 ° C, dark 450mIU / branch 150533-0212 Prolactin immunoassay X142269 -20 ° C, Protect from light 9mIU / branch 150532-0004 Luteinizing hormone (LH) X142270 for -20 ℃, 930 ℃, light shielding 930mIU 150531-201003 Thyrotropin (TSH) use X142271 at -20 ℃, 600μIU 150530-0312

Aobeki's Plancha Grill Trolley is the Best Plancha Trolley. Solid plates for the 2, 3, 4, 5 Burner Gas GriddleEnough storage space for your grill utensils and two wheels for a quick changeover.

Welcome to visit our website, more Placncha Trolley for your choice.And we have Gas Grill , Gas Griddle,Steak Maker.

Plancha Trolley

Plancha Grill Trolley,Best Plancha Trolley,3 Burners Trolley,Plancha Gas Grill With Trolley

GUANGDONG AOBEKI MANUFACTURING CO., LTD , https://www.aobeki.com

Posted on