High frequency resonance electric fatigue testing machine (MOT)

High frequency resonance electric fatigue testing machine (MOT)

Technical parameters High frequency fatigue testing machine The high frequency fatigue testing machine is used to measure the tensile, compression or tensile compression of metals, alloy materials and their components (such as operating joints, fixed parts, spiral moving parts, etc.) at room temperature. Variable load fatigue characteristics, fatigue life, precast cracks and crack propagation tests. After equipped with corresponding test fixtures, the high-frequency fatigue testing machine can carry out three-point bending test, four-point bending test, thin plate tensile test, thick plate tensile test, reinforced steel strip tensile test, chain tensile under sinusoidal load Test, fixed part test, connecting rod test, torsional fatigue test, bending-torsion composite fatigue test, interactive bending fatigue test, CT test, CCT test, gear fatigue test.

(High frequency fatigue testing machine)

Resonance testing machine

The maximum load is 100-250-1000 kN, the equipment selection is from 40KN-300KN, stroke to 12 mm, the operating frequency is 300 Hz, the equipment uses a unique MAGNODYN electromagnetic excitation system that uses resonance to generate vibration.


Main technical parameters and functions of equipment

General: The test equipment can achieve the following related test standards:

Verification method of JJG 556-1988 axial load fatigue testing machine

HB 5287-1996 Metal material axial load fatigue test method

GB / T 6395-2000 Test method for fatigue crack growth rate of metallic materials

GB / T 4161-1984 Metallic material plane strain fracture toughness KIC test method

GB / T 2038-1991 JIC test method for ductile fracture toughness of metallic materials

Host 1) Peak power of power supply: ≤10 KW (including peripheral devices such as cooling and high temperature devices);

2) It should be equipped with corresponding UPS uninterruptible power supply;

3) The effective test working space width: > 680 mm, depth: > 860 mm;

4) Moving range of beam: ≥300mm;

★ 5) One-way maximum tensile or compression static load: not less than ± 100kN;

★ 6) Maximum tensile and compression alternating load: not less than ± 50kN;

7) Dynamic and static loading system, suitable for load 0 ~ 100KN (force value sensor should have advanced acceleration dynamic compensation);

★ 8) Static accuracy of the sensor: within the load range, not more than 0.5% of the load indication value;

★ 9) Sensor dynamic accuracy: within the load range, not more than 0.5% of the load indication value;

10) Frequency range: 50 ~ 300Hz (frequency can be greater than 300Hz);

11) The maximum distance between the lower fixture and the upper fixture should be: not less than 700mm;

★ 12) The coaxiality of the upper and lower chucks: no more than 10%;

13) Displacement measurement and control accuracy: not more than 0.5% of the indicated value.

4.2.2 Wedge-shaped fixtures and accessories are used to clamp flat and round specimens at room temperature, and corresponding clamping blocks should be configured to ensure the use of the following specimens: 1) Thickness of flat specimens a: 0.2-20mm;

2) Diameter of round sample: 2 ~ 20mm.

4.2.3 Room temperature thread fixture

1) Used for room temperature round screw joint samples;

2) Configure internal threaded joints of the following specifications to meet the use of externally threaded specimens of the same specifications: M8 × 1, M11 × 1, M14 × 1, M16 × 1, M22 × 1, M32 × 1;

4.2.4 Test fixtures and accessories for fatigue crack growth rate (da / dN) of metal materials: The following test requirements for samples shall be met: Sample size B (thickness) × W (width): 20 × 80 mm.

4.2.5 Fracture mechanics CT (compact tensile) specimen fixture and accessories: The following specimen test requirements shall be met: CT (compact tensile) specimen size B (thickness) × W (width) is: 12.5 × 25mm.

4.2.6 Strain extensometer and accessories ★ 1) Static accuracy: not more than? 0.5% of the indicated value; ★ 2) Dynamic accuracy: not more than? 1% of the indicated value; 3) Gauge length: 25mm; 4) Strain range : 10%.

4.2.7 Displacement type (COD gauge) extensometer and accessories ★ 1) Dynamic accuracy: not greater than the indicated value? 0.5%; 2) The data collection rate meets the maximum test frequency requirement during the test; 3) The deformation range is not less than? 2.5 mm . 4.2.8 The standard high-temperature device is used for high-temperature fatigue test of metals at 100 ℃ ~ 1200 ℃. 4.2.8.1 Heating furnace 1) A split-type heating furnace with a stainless steel shell; 2) The heating furnace is easy to install in the rack space and has enough space; 3) Heating furnace size range: length / width / height 250 ~ 400mm / 150 ~ 300mm / 150 ~ 300mm; 4) Furnace inner diameter ≥80mm ★ 5) Average heat strip length ≥50mm (temperature fluctuation within the average heat strip ≤ ± 5 ℃, temperature gradient ≤5 ℃); 6) Furnace shell surface temperature ≤ Room temperature + 50 ° C.

4.2.8.2 Temperature measurement and control device ★ 1) Temperature measurement accuracy≤ ± 1 ℃, and room temperature automatic cold junction temperature compensation deviation≤0.50C; 2) Temperature control accuracy≤ ± 1 ℃; 3) Temperature rise overshoot≤5 ℃; 4) The independent control panel should be simple and clear, and manual and automatic PID temperature control settings can be made; 5) The computer can be used to set the temperature control and real-time temperature data collection and heating process graph display.

4.2.8.3 High-temperature fixture 1) It is used in conjunction with the heating furnace for round thread joint samples and plate fatigue samples at high temperatures; 2) Configure M16 internal thread joints to meet the use of external thread samples of the same specifications; 3) Configuration Corresponding fixtures to meet the use of plate samples with a thickness of 0.5 ~ 2mm; 4) During high temperature tests, the safety of the test and equipment should be ensured to be carried out normally. If cooling of fixture connections is required, a circulating water cooling system should be provided.


Main features General performance features:

• High reliability • Unmaintained hydraulic source and valve, pump or cooling system • Simple and easy operation • High frequency operation test throughout the test process • Low energy consumption • The software has many practical values ​​and user-friendly interface operation System high frequency fatigue testing machine

MAGNODYN excitation system This system consists of two parts, an electromagnet and a spring (elastic) fixed in the dynamic loading process. A small but constant air gap is required between the magnet and the operating independent static load system. The dynamic circle permits full operation and testing of stand-alone independent loading systems. The MAGNODYN system design allows specimens or components to use active power directly.

Main technical parameters and functions of equipment

General: The test equipment can achieve the following related test standards:

Verification method of JJG 556-1988 axial load fatigue testing machine

HB 5287-1996 Metal material axial load fatigue test method

GB / T 6395-2000 Test method for fatigue crack growth rate of metallic materials

GB / T 4161-1984 Metallic material plane strain fracture toughness KIC test method

GB / T 2038-1991 JIC test method for ductile fracture toughness of metallic materials

Host 1) Peak power of power supply: ≤10 KW (including peripheral devices such as cooling and high temperature devices);

2) It should be equipped with corresponding UPS uninterruptible power supply;

3) The effective test working space width: > 680 mm, depth: > 860 mm;

4) Moving range of beam: ≥300mm;

★ 5) One-way maximum tensile or compression static load: not less than ± 100kN;

★ 6) Maximum tensile and compression alternating load: not less than ± 50kN;

7) Dynamic and static loading system, suitable for load 0 ~ 100KN (force value sensor should have advanced acceleration dynamic compensation);

★ 8) Static accuracy of the sensor: within the load range, not more than 0.5% of the load indication value;

★ 9) Sensor dynamic accuracy: within the load range, not more than 0.5% of the load indication value;

10) Frequency range: 50 ~ 300Hz (frequency can be greater than 300Hz);

11) The maximum distance between the lower fixture and the upper fixture should be: not less than 700mm;

★ 12) The coaxiality of the upper and lower chucks: no more than 10%;

13) Displacement measurement and control accuracy: not more than 0.5% of the indicated value.

4.2.2 Wedge-shaped fixtures and accessories are used to clamp flat and round specimens at room temperature, and corresponding clamping blocks should be configured to ensure the use of the following specimens: 1) Thickness of flat specimens a: 0.2-20mm;

2) Diameter of round sample: 2 ~ 20mm.

4.2.3 Room temperature thread fixture

1) Used for room temperature round screw joint samples;

2) Configure internal threaded joints of the following specifications to meet the use of externally threaded specimens of the same specifications: M8 × 1, M11 × 1, M14 × 1, M16 × 1, M22 × 1, M32 × 1;

4.2.4 Test fixtures and accessories for fatigue crack growth rate (da / dN) of metal materials: The following test requirements for samples shall be met: Sample size B (thickness) × W (width): 20 × 80 mm.

4.2.5 Fracture mechanics CT (compact tensile) specimen fixture and accessories: The following specimen test requirements shall be met: CT (compact tensile) specimen size B (thickness) × W (width) is: 12.5 × 25mm.

4.2.6 Strain extensometer and accessories ★ 1) Static accuracy: not more than? 0.5% of the indicated value; ★ 2) Dynamic accuracy: not more than? 1% of the indicated value; 3) Gauge length: 25mm; 4) Strain range : 10%.
[img] /uploadfile/folder_1008/07yc_20100807010356.JPG [/ img]
[img] /uploadfile/folder_1008/96xb_20100807010435.JPG [/ img]

DIY&Craft/ Toy

Ningbo Vinny International Trading Co., Ltd , http://www.vinnystationery.com